High Power Laboratory

The High Power Laboratory is Unique in Greece

Contact us

Request a quote completely free of charge or if you feel ready submit your request and we will serve you immediately.

High Power Laboratory

The High Power Laboratory (unique in Greece) performs Short Circuit Tests breaking capacity and Interrupting performance tests in High Voltage, Medium Voltage and Low Voltage Electrical Materials.

Main Tests

  1. Low-voltage switchgear and controlgear assemblies, Low Voltage AC Micro Circuit-breakers, low voltage fuses, portable earthing equipment, Low Voltage relays.
  2. Short time withstand current and peak withstand current tests:
  3. High Voltage AC metal-enclosed switchgear and controlgear, Disconnectors and earthing switch, Load switches, Circuit-Breakers, fuse Cut-out 24kV, Current Transformers, Voltage Transformers, Portable earthing equipment, Surge Arresters, Medium Voltage Cables: Joints, End fittings, terminations, connectors etc.
  4. AC metal-enclosed switchgear and controlgear: Internal arc test 10ka-1s.
  5. Dynamic Ability to withstand short circuit tests for Power transformers 50-1600 KVA, Routine tests,
  6. Visual /dimensional inspection, Sound levels measurements.

Main Equipment

  1. Surge-Power Generator 400 MVA – 24 kV – 9,6 kArms, specially designed for short circuits tests.
  2. Short circuit Test Transformer (Output Current up to 150kArms).
  3. Data Acquisition system with 1Ms/s sampling capability.
  4. Various types of electrical measuring instruments and testing layouts.

Detailed List of Tests - High Power Laboratory

ΕΜΙ-01
INTERNAL ARC TEST FOR AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR, 10KA-1S. NUMBER OF TESTS=2 (IEC 62271-1)
ΕΜΙ-02
INTERNAL ARC TEST FOR AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR, 10KA-1S. NUMBER OF TESTS=3 (IEC 62271-1)
ΕΜΙ-03
INTERNAL ARC TEST FOR AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR, 10KA-1S. NUMBER OF TESTS=4 (IEC 62271-1)
ΕΜΙ-04
ABILITY TO WITHSTAND SHORT CIRCUIT. TEST FOR POWER TRANSFORMERS 50-630KVA (EN17025). NUMBER OF TESTS=9. (IEC 60076-5)
ΕΜΙ-05
MEASUREMENT OF WINDING RESISTANCE FOR POWER TRANSFORMER (EN17025) (IEC 60076-1)
ΕΜΙ-06
MEASUREMENT OF VOLTAGE RATIO AND CHECK OF PHASE DISPLACEMENT FOR POWER TRANSFORMERS (EN17025) (IEC 60076-1)
ΕΜΙ-07
MEASUREMENT OF NO LOAD LOSS AND CURRENT FOR POWER TRANSFORMERS (EN17025) (IEC 60076-1)
ΕΜΙ-08
MEASUREMENT OF LOAD LOSS AND SHORT-CIRCUIT IMPEDANCE FOR POWER TRANSFORMERS (EN17025) (IEC 60076-1)
ΕΜΙ-09
MEASUREMENT OF LOAD LOSS AND SHORT-CIRCUIT IMPEDANCE FOR POWER TRANSFORMERS (EN17025) (IEC 60076-1)
ΕΜΙ-10
MEASUREMENT OF ZERO-SEQUENCE IMPEDANCES FOR POWER TRANSFORMERS (IEC 60076-1)
ΕΜΙ-11
MEASUREMENT OF SOUND LEVELS FOR POWER TRANSFORMERS (IEC 60076-10)
ΕΜΙ-12
MEASUREMENT OF HARMONICS DISTORTION FOR POWER TRANSFORMERS (IEC 60076-1)
ΕΜΙ-13
MEASUREMENT OF D.C. INSULATION RESISTANCE FOR POWER TRANSFORMERS (IEC 60076-1)
ΕΜΙ-13
VISUAL /DIMENSIONAL INSPECTION FOR POWER TRANSFORMERS 50-400KVA (IEC 60076-1)
ΕΜΙ-15
SHORT TIME WITHSTAND CURRENT AND PEAK WITHSTAND CURRENT TESTS FOR AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR 1-20KA- 3S(EN17025) NUMBER OF TESTS: UP TO 5 (IEC 62271-1)
ΕΜΙ-16
SHORT TIME WITHSTAND CURRENT AND PEAK WITHSTAND CURRENT TESTS FOR AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR 1-20KA- 3S(EN17025) NUMBER OF TESTS: UP TO 10 (IEC 62271-1)
ΕΜΙ-17
SHORT TIME WITHSTAND CURRENT AND PEAK WITHSTAND CURRENT TESTS FOR AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR 20-55KA- 3S(EN17025) NUMBER OF TESTS: UP TO 5 (IEC 62271-1)
ΕΜΙ-18
SHORT TIME WITHSTAND CURRENT AND PEAK WITHSTAND CURRENT TESTS : AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR 20-55KA- 3S(EN17025) NUMBER OF TESTS: UP TO 10 (IEC 62271-200, IEC 62271-1)
ΕΜΙ-19
SHORT-CIRCUIT WITHSTAND STRENGTH: LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES 1-20KA- 1S(EN17025) NUMBER OF TESTS: UP TO 5 (EN 61439-1)
ΕΜΙ-20
SHORT-CIRCUIT WITHSTAND STRENGTH FOR LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES 1-20KA- 1S(EN17025) NUMBER OF TESTS: UP TO 10 (EN 61439-1)